r4 - 29 May 2010 - 21:40:16 - PhilipCourtYou are here: carrott.org >  ElectricSaker Web > IPV5135Motor

Thermal Considerations

ProEV are running a pair of 5134WS20 motors with a pair of Simovert inverters. They have photos of the cooling system and a report that it isn't very effective. They say that at 175C winding temperature, water exits the radiator at 40C and after motors and inverters, returns at only 46C.

Rotor Time Constant

First guess at this value for our motor:

T2 = (L1h + L2sig)/R2

With:
L1h = magnetizing inductance (H)
L2sig = Rotor leakage inductance (H)
R2 = Rotor resistance (Ohm)

T = L/r = (L1h + L2sig)/R2
=(6mH + 300 uH)/20mOhm
=0.315 H/Ohm
Edit | WYSIWYG | Attach | Printable | Raw View | Backlinks: Web, All Webs | History: r4 < r3 < r2 < r1 | More topic actions
 
Powered by carrott.org
This site is powered by the TWiki collaboration platformCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.